TW Meng Enterprise Sdn Bhd
3, Ground Floor,
Jalan Sanggul 1F,
Bandar Puteri,
41200 Klang,
Selangor, Malaysia.
+603-3885 3833
+603-3885 3833
+6016-64 03834

2.0HP ECONAVI Non-Inverter Deluxe Air Conditioner CS-C18QKH (CU-C18QKH)

Previous 2 / 8 Next

2.0HP ECONAVI Non-Inverter Deluxe Air Conditioner CS-C18QKH (CU-C18QKH) Air Conditioner Panasonic


Model Indoor (50Hz) CS-C18QKH
Outdoor (50Hz) (CU-C18QKH)
Cooling Capacity Btu/h 18,600
kW 5.44
EER Btu/hW 10.8
Noise Level Indoor (H/L) (dB-A) 45/39
Outdoor (dB-A) (56)
Phase ø 1
Electrical Data Voltage (V) 230
Running Current (A) 7.7
Power Input (W) 1,720
Moisture Removal L/h 3.0
Pt/h 6.3
Air Circulation (Indoor/Hi) m³/min. 16.4
ft³/min. 579
Dimensions Height (mm) 290 (619)
Height (inch) 11-7/16 (24-3/8)
Width (mm) 1,070 (824)
Width (inch) 42-5/32 (32-15/32)
Depth (mm) 240 (299)
Depth (inch) 9-15/32 (11-25/32)
Net Weight kg 12 (38)
lb 26 (84)
Refrigerant Pipe Diameter Liquid Side (mm) ø 6.35
Liquid Side (inch) 1/4
Gas Side (mm) ø 15.88
Gas Side (inch) 5/8
Pipe Extension Chargeless Pipe Length (m) 7.5
Maximum Pipe Length (m) 25
Maximum Elevation Length (m) 20
Additional Refrigerant Gas* (g/m) 20
Power Supply Indoor
Cleaner Air nanoe-G Yes
Anti-Bacterial Filter No
Odour-Removing Function Yes
Removable, Washable Panel Yes
Catechin Air Purifying Filter No
Solar Refreshing Deodorizing Filter No
Comfort ECONAVI Yes
Temperature Wave No
AUTOCOMFORT Yes
Inverter Control No
Mild Dry Cooling No
Quiet Mode Yes
Powerful Mode Yes
Soft Dry Operation Mode Yes
Personal Airflow Creation Yes
Airflow Direction Control (Up Down) No
Manual Horizontal Airflow Direction Control No
Manual Airflow Direction Control (Left Right) No
Sleep Mode Auto-Control No
Automatic Operation Mode (Cooling) Yes
Convenience 24-Hour Dual ON OFF Real Setting Timer No
24-Hour ON OFF Real Setting Timer Yes
12-Hour ON OFF Setting Timer No
LCD Wireless Remote Control Yes
Wired Remote Control No
Reliability Auto Restart No
Random Auto Restart (32 Restart Patterns) Yes
Blue Fin Condenser Yes
Long Piping (Numbers indicate the maximum pipe length) 25m
Top-Panel Maintenance Access Yes
Self-Diagnostic Function No
NOTE * When pipes are not extended from the standard pipe length, the required amount of refrigerant is already in the unit.

Please leave your enquiry here, we will reply as soon as possible.
Name*  
Company Name  
Product Interested  
Quantity  
Email*  
Contact No.*  
Ship to Name  
Shipping Address  
Attachment  
*only support gif, jpeg, jpg, png, pdf
Messages*  

Switch to Mobile Version
Recent Updates
Subscribe Newsletter